OEM Backup Power Supply For Home

Applications:

  • Luxury Villa
  • Communication Base Station
  • Nomadic Farm
  • Residential Electricity

OEM Backup Power Supply For Home Data Sheet

Single Phase ESS Hybrid Inverter
Technical specificationR3KL1R3K6L1R4KL1R4K6L1R5KL1R6KL1
Input(PV)
Max. power(kW)4.64.66677
Max. DC voltage(V)550
MPPT voltage range(V)125~500
Max.input current of single MPPT(A)14
MPPT tracker/strings2/1
AC output
Rated output power(kVA)33.644.656
Max. output current(A)131617.42021.726
Grid voltage/range(V)230/176~270
Frequency(Hz)50/60
PF0.8lagging-0.8leading
THDi<3%
AC output topologyL+N+PE
Battery
Battery voltage range(V)40~58
Max. charging voltage(V)58
Max. charge/discharge current(A)95/62.295/7595/83.395/95.895/104.295/110
Battery typelithium /Lead-acid
Communication interfaceCAN/RS485
EPS output
Rated power(kVA)33.644.656
Rated output voltage(V)230
Rated output current(A)131617.42021.726
Rated frequency (Hz)50 /60
Automatic switching time (ms)<20
THDu<2%
Overload capacity110%,30S/120%,10S/150%,0.02S
General data
Battery chage/dischage efficiency0.95
DC Max.efficiency0.976
Europe efficiencyMPPT efficiency97.0%99.9%
Ingress protectionIP65
Noise emission (dB)<35
Operation temperature- 25℃~ 60℃
CoolingNatural
Relative humidity0~95%(non-condensing)
Altitude2,000m (>2,000 Derating)
Dimensions W*D*H(mm)550*200*515
Weight (kg)25
lsolation transformerNo
Self-consumption(W)<3
Display and communication
DisplayLCD
Interface:RS485/Wifi/4G/CAN/DRMYes/Opt/Opt/Yes/Yes
Safety standardIEC/EN6209-1/-2,IEC/EN62477-1
EMCIEC/EN 61000-6-1,IEC/EN 61000-6-3
On-gridSouth Africa NRS097-2-1:2017,UK G98,G99

Contact us to get a Customized Offer!